Overview
Determination of dn/dc
The dn/dc determination requires calibration of the batch mode instrument with a solvent/solute combination with known dn/dc, typically KCl in water. The calculated constant is not solvent-dependent and may be used for all further measurements. In batch mode, the instrument comes with BI-DNDCW software for use with an external PC. Included with the BI-DNDC instrument is a syringe kit with PEEK™ and Teflon ® tubing, fittings, and syringes.
The sample may be recovered and reconstituted if required. Typically, five or more concentrations, ranging from 0.1 to 10 mg/mL, are recommended. New instrument readings can be performed in a matter of minutes since it only takes ~ 0.5 mL of liquid to flush out the previous sample.
Determination of concentration
In this mode, the BI-DNDC serves as a highly sensitive concentration detector. Even better, with the right wavelength and the BI-MwA, the BI-DNDC becomes part of a system that eliminates GPC/SEC column calibration.
Specifications
Specifications
| Cell Angle | 45° |
|---|
| Cell Volume (Batch Mode) | 8 µL |
|---|
| Dead Volume (Inlet to Cell/Cell to Outlet) | GPC Mode Sample Cell: 0.25 µL, GPC Mode Reference Cell: 100 µL |
|---|
| Batch Mode Sample Cell | 100 µL: Batch Mode Reference Cell: 8 µL |
|---|
| Measurement Ranges (ΔRIU Full Scale)(GPC mode) | 6×10-4, 3×10-4, 1.5×10-4, 7.5×10-5, 3.75×10-5, 1.87×10-5, 9.3×10-6, 4.6×10-6, 2.3×10-6 |
|---|
| no Range | 1.0 to 1.75 RIU |
|---|
| Sensitivity (GPC Mode) | 1.5 ng (Fructose in H2O) |
|---|
| Noise Level | < 2.5×10-9, 25 °C |
|---|
| Temperature Accuracy | ± 0.5 °C |
|---|
| Temperature Stability | ± 0.01 °C |
|---|
| Temperature Range | Ambient to 80 °C |
|---|
| Specify Wavelength | 620 nm, 535 nm or 470 nm, factory set |
|---|
| Tubing I.D.: GPC Mode Sample Cell | 0.25 mm, GPC Mode reference cell: 0.5 mm; Batch Mode sample cell: 0.5 mm |
|---|
| Batch Mode Reference Cell | 0.5 mm |
|---|
| Flow Rate (typical/maximum) | 1.0/3.0 mL/min (Analytical Mode), 5.0/12.0 mL/min (Preparation Mode) |
|---|
| Time Constant | 0.1 to 2 seconds |
|---|
| Analog Signal Output | 1 and 10 volt bipolar, full scale |
|---|
| Digital Signal Output | RS-232/COM port |
|---|
| Software | BI-DNDCW for Batch Mode measurements |
|---|
| Data Transfer Rate (baud) | 4800, 9600, 19200, 38400, 57600, 115200 |
|---|
| Digital Inputs | Flush, Zero, Sync, Error |
|---|
| Weight | 8 kg |
|---|
| Size | 160 x 175 x 340, mm |
|---|
| Certifications | CE Marked |
|---|
A policy of continual improvement may lead to specification changes.