Light Scattering Fundamentals

Twenty-four short modules on the things that actually go wrong at the bench, and the science underneath them. Each is five sections and a short quiz, with a completion certificate when you pass.

Training the next generation of particle characterization experts, helping customers every step of the way.

Product focus 200SM NanoBrook TurboCorr General
Module 01
General

Dust: The Particle That Lied to You

Recognizing, diagnosing, and defeating dust contamination in DLS. The d⁶ problem, the Baseline Index, and not filtering away your own data.

5 sections · ~10 min
Start module →
Module 02
General

Your Sample Is Too Concentrated and So Are You

Count rate, the NDF wheel, multiple scattering, and the radical idea that dilution makes data better.

5 sections · ~10 min
Start module →
Module 03
NanoBrook

Zeta Potential and the ±30 mV Threshold of Trust

Surface charge, colloidal stability, DLVO, the isoelectric point, and salt's double-edged role.

5 sections · ~10 min
Start module →
Module 04
General

The Hydrodynamic Diameter Hoax

Why DLS reads larger than TEM, intensity vs. number vs. volume weighting, and reading PDI honestly.

5 sections · ~10 min
Start module →
Module 05
NanoBrook

When Your Zeta Potential Won't Sit Still

PALS vs. ELS, the reference beam, self-peaking, and the short checklist behind irreproducible zeta.

5 sections · ~10 min
Start module →
Module 06
General

Why We Add Salt (No, Not for Flavor)

Ionic strength control, the Debye length, salting out, and filtering the stock you spike in.

5 sections · ~10 min
Start module →
Module 07
200SM

Aligning the BI-200SM Without Crying

Toluene, the I·sin(θ) plot, vernier offsets, and not chasing dust with a screwdriver.

5 sections · ~10 min
Start module →
Module 08
200SM

Rods, Disks, and the Particles That Refuse to Be Spheres

Anisotropic particles, multiple decay rates, Perrin equations, and the backscatter trap.

5 sections · ~10 min
Start module →
Module 09
200SM

Static Light Scattering: Weighing Molecules With Light

Molecular weight, radius of gyration, Rg/Rh shape, the plot zoo, and the Debye 12 nm limit.

5 sections · ~10 min
Start module →
Module 10
200SM

The APDx Detector: Counting Photons Without Lying About It

Dead time, the forgotten 25 ns setting, dark counts, detector aging, and the linear range.

5 sections · ~10 min
Start module →
Module 11
General

The Case of the Sample That Wasn't There

Non-aqueous solvents, contrast matching, viscosity-unit traps, glass vs. plastic, and number fluctuations.

5 sections · ~10 min
Start module →
Module 12
TurboCorr

The Autocorrelation Function: Where Size Actually Comes From

Correlation decay, Γ = Dᵗq², the Siegert relation, cumulants vs. CONTIN, and reading the baseline.

5 sections · ~10 min
Start module →
Module 13
NanoBrook

The BI-ZTU Auto-Titrator: Automating Your Way to a Stable Formulation

Automated pH titrations, finding the IEP, additive optimization by zeta plateau, and the pump that won't prime.

5 sections · ~10 min
Start module →
Module 14
NanoBrook

Why Is My Zeta Potential Positive? A Sign-Reversal Mystery

Electrode orientation, the ZR5 check, surface potential vs. zeta, specific ion adsorption, and the IEP.

5 sections · ~10 min
Start module →
Module 15
NanoBrook

Conductance vs. Conductivity: A Distinction That Costs You Hours

µS vs. µS/cm, why the NanoBrook reports conductance, and reading it as a pre-zeta health check.

5 sections · ~10 min
Start module →
Module 16
General

Temperature Equilibration: The Fifteen Minutes You Keep Skipping

Stokes–Einstein, equilibration times, convection faking diffusion, the 300 s default, and viscosity.

5 sections · ~10 min
Start module →
Module 17
TurboCorr

Cross-Correlation and Afterpulsing: Two Detectors, One Truth

The short-delay artifact, the two-detector cure, the honest 2D-vs-3D distinction, and DWS.

5 sections · ~10 min
Start module →
Module 18
NanoBrook

The Metal-Oxide IEP Ladder (and Why Mixing Them Is Dangerous)

IEPs from silica to magnesia, titration hysteresis, and the mixed-oxide hetero-aggregation trap.

5 sections · ~10 min
Start module →
Module 19
General

The .bak Archive: Saving Data Your Future Self Won't Curse

Portable archives, the dual filtered/unfiltered ACF storage, and reporting honest significant figures.

5 sections · ~10 min
Start module →
Module 20
General

Is the Laser Actually Dead? A Field Autopsy

Standby and shutter impostors, contrast-matched samples, the <1 mW death test, and the reference-beam early warning.

5 sections · ~10 min
Start module →
Module 21
200SM

Is It the Detector? Diagnosing a Sick APD or PMT

Dark counts as a vital sign, aging and saturation, the connector that destroys PMTs, and laser-vs-detector triage.

5 sections · ~10 min
Start module →
Module 22
TurboCorr

Baselines, Intercepts, and Bad Fits

Calculated vs. measured baselines, autoslope misfires, the intercept as a health check, and reading a fit before trusting it.

5 sections · ~10 min
Start module →
Module 23
200SM

Don't Break the Instrument: A Hardware Care Survival Guide

The interlock-free laser, the PMT-killing connector, the fingerprint-hating vat, the extinct cable, and safe module return.

5 sections · ~10 min
Start module →
Module 24
General

Counting Without Counting: The Concentration Tool and Other Clever Tricks

Scattering as a concentration proxy, the dn/dc error doubler, the BI-870 nonpolar niche, and inference within assumptions.

5 sections · ~10 min
Start module →